Stored energy does not all come back
After a full charge and discharge cycle, less energy comes back than went in. Round-trip efficiency describes that difference. Your installer enters a suitable value for your battery. This means a small gap between cheap electricity now and more expensive electricity later may not be enough to make charging worthwhile once losses are considered.
More activity is not always better
During cost optimisation, a configured wear cost per charged kWh or minimum price margin can help determine whether a cycle makes sense. If the expected benefit does not cover configured costs and losses, your battery may be less active. That can fit the chosen strategy. Your installer explains how the comparison works for your battery.
Solar electricity has a value too
Grid charging is assessed against your purchase price. Storing solar means you cannot export that energy immediately, potentially giving up income, so both tariffs matter. Battery strategy and minimum charging targets also play a part. Local schedules need active local storage control; configured external control can take precedence over those schedules.
Why your battery may take a quieter day
Today's electricity prices hardly vary. Your battery has configured efficiency and wear costs. Charging now to use the energy later may offer too little benefit to cover those losses and costs. The battery can therefore be less active under cost optimisation. Your installer can review this with you, without changing settings simply to create more visible activity.
For installers: give battery use a sound basis
- Enter a suitable round-trip efficiency for the installed battery.
- Configure the available wear cost or minimum price margin.
- Verify purchase and export tariffs and the chosen battery strategy.
- Check minimum charging targets, active local storage control and any external control.
Technical documentation