Your total usage is only part of the picture
Your charger, heat pump and household appliances may load different phases. Your connection has both an overall power limit and current limits on individual phases. A low total reading can therefore hide a busy phase. Your installer checks the current on each phase and how your devices are physically connected.
Your devices determine what can be adjusted
SmartgridOne takes phase current limits into account when controlling connected devices. Most devices accept a symmetrical command across their phases, so those phases are normally controlled together. Software cannot turn this into independent phase control. The room for compensation depends on the supported device and available power, which your installer checks under typical loads.
Good wiring comes first
Physically redistributing badly uneven loads remains the recommended first solution. If explicit three-phase planning is needed, your installer verifies that meter phases match the device connections and tests realistic combinations of import and export. The EMS helps manage configured limits; it does not replace electrical protection or correct wiring.
Your car charges on a busy phase
Your total usage looks reasonable, but the phase supplying your charger also powers several other appliances. Your installer checks the readings, wiring and charger controls. Reducing charging may help respect the current limit. If the imbalance persists, redistributing the loads may be more appropriate than relying on a symmetrical battery command.
For installers: before activation
- Check grid system, breaker rating and phase measurements.
- Verify wiring and any required phase mapping.
- Confirm supported controls and their physical limits.
- Test realistic loads and correct wiring where needed.
Technical documentation
Your installer can find connection guides, detailed settings and installation instructions in our technical documentation.