GRID COMPLIANCE & REMOTE CONTROL

Telecontrol without the complexity

Keep energy assets compliant, controllable and ready for the grid’s next requirement. SmartgridOne connects grid-operator signals to your installation and turns them into safe, measurable actions across batteries, PV, EV charging and flexible loads.

FROM OPERATOR SIGNAL TO ASSET RESPONSE
↔Grid operatorRTU · IEC 60870-5-104
SMARTGRIDONEControl layerValidated setpoint
⌁Grid connectionKept within the limit
◉BatteryCharges or discharges
✦Solar (PV)Curtailed when needed
Signal in · decision · measured feedback

WHAT IS TELECONTROL?

Remote commands become predictable site actions

Telecontrol lets a grid operator monitor an installation remotely and intervene when needed: reading power, voltage and current, but also imposing power limits or disconnecting.

The communication runs over an RTU, using the protocol required by the operator. SmartgridOne treats every signal as a clear operating constraint while local safety limits remain active.

01
ReceiveOperator command arrives through the approved interface.
02
ValidateSignal, priority and site limits are checked.
03
ActAssets respond with controlled ramp rates.
04
ReportMeasured response is sent back for verification.
THE CONTROL LOOP, VISUALISED
RTUGrid operator
SmartgridOneController
AssetsBattery · PV
HARDWARE EMERGENCY STOP

TELECONTROL INTEGRATION, END TO END

One loop, checked from signal to response

A project is ready when the complete chain works: the operator commands, the controller regulates, and the site reports back with real measurements.

  • RTU interface in the protocol the grid operator requires.
  • Local IO safety layer for emergency stop and fallback behaviour.
  • Measured validation for active power, reactive power and feedback.
  • Guided certification with the project team and grid operator.

BUILT FOR REAL PROJECTS

A telecontrol integration that works beyond the diagram

Requirements differ by country, connection and operator. We configure the signals, priorities and fallback behaviour around the approved project design.

01 · OPERATOR-SPECIFIC

Configured for the grid code

Signal lists, setpoints and communication are aligned with the operator involved in your project.

02 · SAFE BY DESIGN

Predictable under pressure

Local limits and fail-safe behaviour remain active when a communication link is interrupted.

03 · MEASURED RESPONSE

Tested with real values

We validate the full control loop from the operator interface to the physical response on site.

04 · READY FOR HANDOVER

Evidence your team can use

Clear signal lists, commissioning results and handover support make certification easier.

WHERE TELECONTROL ADDS VALUE

One control layer for connected energy assets

SmartgridOne coordinates the response across compatible devices and keeps telecontrol aligned with local optimisation, market participation and site-level priorities.

  • Battery energy storage systems
  • PV installations with curtailment requirements
  • Hybrid PV and battery projects
  • EV charging and flexible industrial loads
  • Aggregated portfolios and virtual power plants
SmartgridOneone control layer
PV
BESS
EV
LOAD
Grid signal + local energy flows
Grid complianceactive
SmartgridOnecontrol
Local optimisationready
Market participationconnected
One place to configure priorities, monitor performance and extend the installation.

WHY ENIRIS

Control that fits your entire energy strategy

Telecontrol does not have to be an isolated box next to your EMS. With SmartgridOne, grid signals, local energy flows and commercial optimisation are handled in one platform.

That gives project teams one place to configure priorities, monitor performance and extend the installation as requirements change.

FREQUENTLY ASKED QUESTIONS

Questions about telecontrol?

When is telecontrol required?

That depends on the country, grid operator, connection agreement and characteristics of the installation. We help identify the applicable requirements during project design.

Which protocols and interfaces are supported?

The interface depends on the project. SmartgridOne can work with operator-approved RTU and communication setups, including IEC 60870-5-104 and digital I/O where required.

What happens if communication is interrupted?

The controller follows the configured fallback and safety rules. Local limits and site protection remain active, and the behaviour can be tested during commissioning.

Can telecontrol run with market optimisation?

Yes. Grid-operator commands are treated as control constraints with the agreed priority. Remaining flexibility can continue to support local optimisation or market strategies.

READY FOR THE NEXT PROJECT?

Planning a project with telecontrol requirements?

Share your country, grid operator, connection size and asset mix. We will help map the required signals, interfaces and control logic into a project-ready solution.

Talk to our specialists →